1

Transformer Tester Jobs (NOW HIRING)

Transformer Technician

Humboldt, TN

$17.75 - $24.25/hr

Work side-by-side with the Field Service team to support transformer maintenance, testing, and repair activities * Help prepare tools, equipment, and job sites before and during projects * Assist ...

Preferred not required - 2 years or more experience in high voltage transformer testing - HiPot, load-loss/no-load-loss, impedance, impulse, temperature rise, etc. * Preferred not required - 3 years ...

Preferred not required - 2 years or more experience in high voltage transformer testing - HiPot, load-loss/no-load-loss, impedance, impulse, temperature rise, etc. * Preferred not required - 3 years ...

Preferred not required - 2 years or more experience in high voltage transformer testing - HiPot, load-loss/no-load-loss, impedance, impulse, temperature rise, etc. * Preferred not required - 3 years ...

Tester B DSW

San Carlos, CA · On-site

$33.44 - $34.09/hr

The largest, American-owned medium power transformer manufacturer in the United States and the ... What You'll Do As a Tester, you'll play a hands-on role in performing control circuit and ...

Transformer Repair

Denver, CO · On-site

$27.98 - $45.60/hr

Preferred not required - 2 years or more experience in high voltage transformer testing - HiPot, load-loss/no-load-loss, impedance, impulse, temperature rise, etc. * Preferred not required - 3 years ...

Transformer Repair

Denver, CO · On-site

$27.98 - $45.60/hr

Preferred not required - 2 years or more experience in high voltage transformer testing - HiPot, load-loss/no-load-loss, impedance, impulse, temperature rise, etc. * Preferred not required - 3 years ...

Showing results 21-40

Transformer Tester information

See salary details

$10

$38

$62

How much do transformer tester jobs pay per hour?

As of Jul 24, 2026, the average hourly pay for transformer tester in the United States is $38.36, according to ZipRecruiter salary data. Most workers in this role earn between $21.39 and $50.72 per hour, depending on experience, location, and employer.

What is a testing transformer?

A testing transformer is a device used by transformer testers to evaluate the performance and integrity of electrical transformers. It helps measure parameters such as voltage, current, and insulation resistance to ensure proper operation and safety. Testing often involves specialized equipment and adherence to industry standards.

What does a typical workday look like for a Transformer Tester?

A typical workday for a Transformer Tester involves conducting electrical tests on transformers to validate performance and detect faults, both in the field and in manufacturing or repair facilities. You’ll routinely prepare test setups, operate diagnostic equipment, record and analyze results, and collaborate with engineers and maintenance personnel to address any issues identified. The role may require some travel to customer sites or substations, and often involves working as part of a team to adhere to safety protocols and project timelines. This hands-on, detail-focused environment provides opportunities to develop specialized technical expertise and progress into senior testing, quality assurance, or supervisory positions over time.

What is the 80% rule for transformers?

The 80% rule for transformers refers to the guideline that a transformer should operate at no more than 80% of its rated capacity to ensure reliability and prevent overheating. Transformer testers often verify this by measuring load and temperature during testing to confirm safe operating limits, especially in maintenance and troubleshooting tasks.

Is there a legit product tester job?

A transformer tester job is a legitimate role in electrical testing and maintenance, involving inspecting and evaluating transformers for safety and performance. These positions typically require technical skills, knowledge of electrical systems, and sometimes certifications such as OSHA or electrical licenses. Such jobs are often found in utility companies, manufacturing, or maintenance firms and are generally stable employment opportunities.

What are the key skills and qualifications needed to thrive in the Transformer Tester position, and why are they important?

To thrive as a Transformer Tester, you need a solid understanding of electrical theory, troubleshooting skills, and a background in electrical engineering or a related technical field. Experience with testing equipment such as power analyzers, insulation resistance testers, winding resistance meters, and knowledge of safety standards like OSHA or NETA certification is highly valuable. Strong attention to detail, problem-solving abilities, and clear communication are important soft skills in this role. These skills ensure accurate diagnosis, safe operations, and effective teamwork in high-stakes testing environments.

How much do transformer testers make?

Transformer testers typically earn between $50,000 and $80,000 annually, depending on experience, certifications, and location. Entry-level positions may start lower, while experienced technicians with specialized skills can earn higher wages, especially if working overtime or in industrial environments.

What is a Transformer Tester job?

A Transformer Tester is responsible for inspecting, testing, and diagnosing electrical transformers to ensure they function properly and meet industry standards. This job involves using specialized testing equipment to measure parameters like voltage, insulation resistance, and load performance. Transformer Testers work in manufacturing plants, utility companies, or service organizations, performing quality control and troubleshooting electrical faults. They also document test results and collaborate with engineers to recommend repairs or improvements. Strong technical skills in electrical testing and safety procedures are essential for this role.

More about Transformer Tester jobs
What are the most commonly searched types of Transformer Tester jobs? The most popular types of Transformer Tester jobs are:
What states have the most Transformer Tester jobs? States with the most job openings for Transformer Tester jobs include:
Infographic showing various Transformer Tester job openings in the United States as of July 2026, with employment types broken down into 93% Full Time, 4% Part Time, and 3% Contract. Highlights an 65% Physical, 1% Hybrid, and 34% Remote job distribution, with an average salary of $79,791 per year, or $38.4 per hour.
Field Service Electrical Test Specialist (FSET)

Field Service Electrical Test Specialist (FSET)

Pennsylvania Transformer Technology LLC

Canonsburg, PA

$57K - $76K/yr

Other

Posted 8 days ago


Job description

Description

The Power Transformer Testing Specialist is responsible for performing advanced diagnostic testing, commissioning, troubleshooting, and condition assessment of Medium, Large, EHV (Extra High Voltage), and UHV (Ultra High Voltage) power transformers. This role requires expert-level knowledge of IEEE transformer testing standards, electrical testing methodologies, and industry test equipment. The specialist ensures the reliable operation of critical power assets by conducting high-accuracy test procedures, compiling complex data, and providing technical reports, working collaboratively with engineering.

Requirements

Transformer Testing & Diagnostics

  • Perform advanced field testing on Medium, Large, EHV, and UHV transformers in accordance with IEEE standards (including IEEE C57 series).
  • Ability to execute the full suite of transformer diagnostic testing, such as: 
    • Insulation Power Factor (Doble PF/Tan Delta)
    • Excitation current testing
    • Winding resistance testing
    • TTR (Turns Ratio Testing)
    • Sweep Frequency Response Analysis (SFRA)
    • Dielectric Frequency Response (DFR)
    • Leakage Reactance / Short-circuit impedance
    • Capacitance and insulation resistance measurements
    • Partial discharge testing (when required)
    • Oil sampling, dissolved gas analysis (DGA), and moisture assessment
  • Operate and      maintain advanced test equipment from OEMs such as Doble, Omicron, Megger, Vanguard, and others.

Commissioning & Field Service

  • Lead and support transformer energization, acceptance testing, and commissioning activities for new or refurbished power transformers.
  • Verify compliance with utility, EPC, and OEM specifications.
  • Perform on-site troubleshooting for abnormal transformer conditions and support root-cause      investigations.
  • Collaborate with engineering to analyze test results and trends to evaluate      transformer health and recommend corrective actions.
  • Compile and support the preparation of detailed technical data with interpretations,      conclusions, and maintenance recommendations.
  • Communicate test results and findings to engineering teams, utility clients, and      project managers.

Safety & Compliance

  • Follow as OSHA, NFPA 70E, and company safety procedures during testing and field      service work.
  • Ensure testing is performed in alignment with IEEE, ASTM, NETA, and OEM guidelines.
  • Support the maintenance, calibration, and proper care of all test instruments and PPE.

Technical Leadership

  • Serve as the field process expert on transformer testing, working with Engineering.
  • Mentor junior technicians and assist with training on field testing methods.
  • Participate in continuous improvement of testing procedures, workflows, and      documentation.

Required Qualifications

  • Associate or bachelor's degree in electrical engineering, Power Engineering, or related field (or equivalent experience).
  • 5+ years of experience performing transformer testing in utility, industrial, EPC, or field-service environments.
  • Expert knowledge of IEEE C57 transformer testing standards and field-testing practices.
  • Proficiency with transformer testing instruments (Doble, Omicron, Megger, etc.).
  • Strong understanding of transformer construction, theory, insulation systems, and failure modes.
  • Ability to read and interpret technical drawings, schematics, and OEM manuals.
  • Excellent analytical, troubleshooting, and problem-solving skills.
  • Strong written and verbal communication abilities.
  • Ability to travel to job sites, sometimes on short notice.

Preferred Qualifications

  • NETA Level III  or IV certification (or equivalent experience).
  • Experience with EHV/UHV transformer commissioning (230kV-765kV and above).
  • Training of certification in SFRA, PD testing, or advanced diagnostic methods.
  • Experience working with EPCs, IOUs, IPPs, or large industrial clients.
  • Familiarity with digital transformer monitoring systems.
  • Experience with High Voltage breakers a plus

Work Environment & Physical Requirements

  • Field-based role requiring work at substations, power plants, industrial sites, and service centers.
  • Ability to work outdoors in varying weather conditions.
  • Ability to lift 50 lbs., climb ladders, and work around high voltage equipment safely.