2

Remote Bms Design Engineer Jobs in Oregon (NOW HIRING)

This role is remote. What You'll Do (Key Responsibilities) * Develop and maintain electrical ... Exposure to BMS/DCIM integration, BACnet/Modbus, and the electrical side of controls handoffs.

The BESS Engineer II is responsible for the design, development, and implementation of BESS ... batteries, inverters, BMS(Battery Management Systems), and grid interconnection equipment.

Senior SCADA Engineer, Design (Remote)

OR · On-site +1

$104K - $143K/yr

Assigned SCADA design, programming, and commissioning tasks are completed accurately and on ... recruiter. #LI-Remote Job Number: J13743 If you're interested in a meaningful career with a ...

New

Location. This role is remote with extensive travel. What You'll Do (Key Responsibilities ... Lead BMS, EPMS, and DCIM integration, validation, and operational readiness testing activities

Fire Protection Engineer

$140K - $165K/yr

Multi-state Work Environment: Hybrid/Remote Preferred to be at Dudek office, remote is ... Design, implement, and oversee fire suppression (such as water mist), detection (UV/IR), gas ...

Software Engineer (US-Remote) ID: 1191 Location: US-Remote or Marlton, NJ area Description A ... Design, develop, test, and deploy scalable applications, APIs, and microservices using modern ...

Electrical III - Cyber Security

OR · On-site +1

$79K - $104K/yr

Perform electrical engineering systems design for building construction. * Design lighting, power ... We have paid time off, flex-time schedules, remote work options and a 401k plan and employee perk ...

The HV SCADA Engineer II will provide intermediate level engineering support for the design ... This role can be fully remote or located in one of our offices in Bend, OR, San Diego, CA, or ...

The HV SCADA Engineer II will provide intermediate level engineering support for the design ... This role can be fully remote or located in one of our offices in Bend, OR, San Diego, CA, or ...

Senior SCADA Engineer, EPC (Remote)

Bend, OR · On-site +1

$110K - $151K/yr

The Senior SCADA Engineer, EPC will lead and execute SCADA and PPC engineering workstreams for the ... Define and implement SCADA design standards and best practices aligned with company objectives.

Engineer

Portland, OR · On-site +1

In addition, your work will potentially take you into the remote and scenic areas of our ... Design, develop, modify, and evaluate systems, process, or facilities to support Company objectives ...

Engineer

Portland, OR · On-site +1

In addition, your work will potentially take you into the remote and scenic areas of our ... Design, develop, modify, and evaluate systems, process, or facilities to support Company objectives ...

Substation Engineer 2 (Remote)

OR · On-site +1

$98K - $125K/yr

The Substation Engineer is responsible for the design, implementation, and testing of electrical ... This role is fully remote. Specific location details and expectations will be discussed during the ...

next page

Showing results 1-20

Remote Bms Design Engineer information

What is a remote BMS design engineer?

Remote BMS (Battery Management System) Design Engineers are professionals who design, develop, and optimize battery management systems for various applications, such as electric vehicles or renewable energy storage, while working remotely. They focus on creating hardware and software solutions that monitor and control battery performance, safety, and longevity. Working remotely allows these engineers to collaborate with teams, create schematics, develop algorithms, and test systems using digital tools and communication platforms.

What are the key skills and qualifications needed to thrive as a remote BMS design engineer, and why are they important?

To thrive as a Remote BMS (Building Management System) Design Engineer, you need expertise in electrical engineering, control systems, and HVAC principles, typically supported by a relevant engineering degree. Familiarity with BMS software platforms like Siemens Desigo, Schneider EcoStruxure, or Honeywell, and proficiency in AutoCAD or similar CAD tools, are commonly required. Strong problem-solving abilities, effective communication, and self-motivation are crucial soft skills, especially when collaborating remotely with multidisciplinary teams. These skills and qualifications are essential to deliver robust, energy-efficient BMS solutions and ensure seamless project execution across diverse client sites.

What are some common challenges faced by remote BMS design engineers and how can they be addressed?

Remote BMS Design Engineers often encounter challenges such as coordinating effectively with cross-functional teams across different time zones, ensuring robust communication, and managing project timelines without in-person collaboration. To address these, leveraging project management tools, maintaining clear documentation, and scheduling regular virtual meetings are essential. Additionally, staying updated with the latest BMS technologies and cybersecurity standards is important for delivering reliable and secure systems. Developing strong self-motivation and proactive communication skills can greatly enhance success in this remote role.

What is the difference between Remote Bms Design Engineer vs Remote Battery Management System (BMS) Technician?

AspectRemote Bms Design EngineerRemote BMS Technician
CredentialsBachelor's in Electrical/Electronic Engineering, BMS certificationsTechnical diploma or certification in BMS maintenance
Work EnvironmentDesign offices, remote collaboration, project planningFieldwork, troubleshooting, on-site or remote support
Industry UsageProduct development, system design, engineering firmsInstallation, maintenance, repair services

The Remote Bms Design Engineer focuses on designing and developing BMS systems, requiring engineering expertise and certifications. In contrast, the Remote BMS Technician primarily handles installation, troubleshooting, and maintenance tasks. Both roles are essential in the BMS industry but differ in responsibilities, skills, and work environments.

What job categories do people searching Remote Bms Design Engineer jobs in Oregon look for?

The top searched job categories for Remote Bms Design Engineer jobs in Oregon are:

What cities in Oregon are hiring for Remote Bms Design Engineer jobs?

Cities in Oregon with the most Remote Bms Design Engineer job openings:

Electrical Design Engineer

Armada

OR • On-site, Remote

Full-time

Medical, Dental, Vision, Retirement, PTO

Posted 4 days ago


Job description

 
About the role

Armada builds and deploys ruggedized, modular, containerized data centers that bring high-density AI compute to locations where traditional data centers cannot go. We are scaling production across multiple international markets, with deployments ranging from multi-megawatt GPU clusters to large-scale multi-unit campuses at up to 400 kW/rack. 

Armada needs an Electrical Design Engineer to work directly under the Senior Electrical Design Engineer on the power and integration team. This is a hands-on design role: you will own the electrical design for modular units from single-line through commissioning, review vendor submittals, and directly support manufacturing partners and deployment teams across multiple time zones. You will not be writing specs from an ivory tower - you will be on calls with manufacturers early in the morning, reviewing arc flash studies at noon, and answering field questions from a commissioning crew in the evening. 

This role is for someone who wants to ship hardware, not produce reports. 

Location. This role is remote.

What You'll Do (Key Responsibilities)

  • Develop and maintain electrical designs for modular containerized data centers: single-line diagrams, load calculations, panel schedules, grounding, cable sizing, and raceway layouts across multiple low-voltage distribution standards (480 V and other international LV systems). 
  • Run protective device coordination, arc flash, and short-circuit studies in SKM, ETAP, or equivalent. Produce labels and coordination reports that will be used in the field. 
  • Review and redline vendor submittals for UPS systems, battery systems, cooling distribution units, switchgear, main distribution boards, PDUs, and generator/ATS packages. Hold vendors accountable to the spec; flag discrepancies early. 
  • Support manufacturing partners: answer RFIs, resolve conflicts on layout and piping/cable routing, and participate in factory witness testing. 
  • Contribute to multi-jurisdictional compliance across a range of international electrical, fire, and mission-critical facility codes, and coordinate with local Authorities Having Jurisdiction. 
  • Produce clear engineering documentation: Statements of Requirements, design basis memos, block diagrams, and commissioning procedures. If you hate writing, this is not the job. 
  • Work alongside mechanical, controls, structural, and fire protection engineers - and with external consultants. You will be expected to push back when something is wrong, regardless of seniority. 
  • Support field commissioning and troubleshooting, including occasional international travel to manufacturing partner sites, deployments, and trade events. 

Required Qualifications

  • Bachelor's degree in Electrical Engineering from an accredited program. 
  • 3-7 years of post-degree experience in electrical design, with at least 2 years in data centers, mission-critical facilities, industrial power, or equivalent complex power distribution. 
  • Demonstrated working knowledge of the NEC (NFPA 70) and, ideally, one or more IEC-based national codes. Multi-jurisdictional design experience is a strong plus. 
  • Hands-on experience with protection coordination and arc flash software (SKM PowerTools, ETAP, EasyPower, or similar). 
  • Proficiency with AutoCAD Electrical and/or Revit MEP, plus Bluebeam Revu (or equivalent) for submittal markup. 
  • Familiarity with UPS systems (double-conversion topology, battery sizing, parallel operation), medium- and low-voltage switchgear, transformers, and generator/ATS integration. 
  • Ability to read mechanical and structural drawings well enough to catch interdisciplinary conflicts before they hit manufacturing. 
  • Clear written communication. You will be writing RFI responses, submittal reviews, and technical memos read by vendors and executives. 

Preferred Experience and Skills

  • PE or EIT licensure is a plus; neither is required. 
  • Experience with containerized or modular/prefabricated data center products. 
  • Knowledge of high-density liquid-cooled GPU systems and their electrical implications - inrush, harmonics, rack-level power distribution, busway. 
  • Working familiarity with battery chemistries beyond VRLA and lithium-ion, and with UL 9540A or equivalent large-scale battery testing requirements. 
  • Familiarity with NFPA 70E, NFPA 75/76, NFPA 110, and NFPA 855 as they apply to mission-critical and energy storage installations. 
  • Experience coordinating with multiple AHJs and international insurance bodies on mission-critical approvals. 
  • Exposure to BMS/DCIM integration, BACnet/Modbus, and the electrical side of controls handoffs. 
  • Experience working with external manufacturing partners and consultants across multiple time zones.

Compensation

For U.S. Based candidates: To ensure fairness and transparency, the starting base salary range for this role for candidates in the U.S. are listed below, varying based on location experience, skills, and qualifications.

We use a geographic pay structure based on cost-of-labor markets. 

  • Tier 1 (e.g., SF Bay Area, NYC, Seattle): $130,824 - $163,530
  • Tier 2 (most U.S. metro areas): $113,760 - $142,200 
  • Tier 3 (other cities): $108,072 - $135,090

Final compensation will be determined by experience, scope, and level, and may vary from the posted range. 

In addition to base salary, this role will also be offered equity and subsidized benefits (details available upon request).

Benefits

  • Competitive base salary and equity
  • Medical, dental, and vision (subsidized cost)
  • Health savings accounts (HSA), flexible spending accounts (FSA), and dependent care FSAs (DCFSA)
  • Retirement plan options, including 401(k) and Roth 401(k)
  • Unlimited paid time off (PTO)
  • 14 paid company holidays per year

#LI-AB1

#LI-Remote